STEP #1
STOP THE UNIT WITH THE HEAD DOWN & THE WEIGHTS
IN THE UP POSITION. ABOUT 5 DEGREES TOWARD THE
HEAD OF THE UNIT, SET THE PUMPING UNIT BRAKE,
LOCK & TAG OUT OF THE PUMPING UNIT.
-
STEP#2
-
OPTION # 1
THE ADJUSTABLE BASE CLAMP CAN BE INSTALLED
IN TWO DIFFERENT PLACES. THE FIRST POINT IS
ON THE CROSS BASE BEAM. THE SECOND POINT IS
ON THE BASE OF THE UNIT BEHIND THE CROSS
BASE BEAM.
-
OPTION # 2
THE COASTAL
TYPE BASE CLAMP MUST SLIDE AROUND THE 3” I
BEAM WHILE THE HOOKS SLIDE UNDER THE UNIT &
HOOK ON THE BACK SIDE OF THE BOTTOM BEAM.
-
STEP#3
USING FIBERGLASS LIFTING POLE PICK UP THE 3/8
ROPE IN THE CENTER. HANG THE ROPE ON THE HOOK.
-
STEP#4
USING THE FIBER GLASS POLE PICK THE CABLE UP
JUST BELOW THE EYE OF THE CABLE. HOIST UP THE
CABLE WITH THE ROPE & GUIDE THE CABLE EYE ON THE
HOOK USING THE FIBER GLASS POLE.
-
STEP#5
INSTALL THE HAIR PIN ON THE APPROPRIATE CABLE
BUTTON.
-
STEP #6
CONNECT TURNBUCKLE TO THE HAIRPIN.
-
STEP #7
CONNECT TURNBUCKLE TO THE BOTTOM BASE CLAMP.
-
STEP #8
TIGHTEN CABLE VIA THE TURNBUCKLE WITH NO SLACK
IN THE CABLE.
-
STEP#9
RELEASE THE PUMPING UNIT BRAKE “VERY SLOWLY” TO
INSURE THAT ALL THE WEIGHT IS NOW LOADED ON THE
CABLE. NOW RESET THE PUMPING UNIT BRAKE.
THE PUMPING UNIT IS NOW SAFE TO WORK ON OR
AROUND. REVERSE THE PROCEDURE TO REMOVE THE TIE
DOWN SYSTEM FROM THE UNIT