Click Photos
to Enlarge
(Back-button to return) |
Lockout / Blockout Procedure
for
HOBBLE-CLAMP Attachments |
 |
STEP #1
STOP THE UNIT WITH THE HEAD DOWN & THE
WEIGHTS IN THE UP POSITION. ABOUT 5 DEGREES TOWARD THE HEAD OF
THE UNIT, SET THE PUMPING UNIT BRAKE, LOCK & TAG OUT OF
THE PUMPING UNIT. |
 |
STEP#2
THE ADJUSTABLE BASE CLAMP CAN BE INSTALLED IN TWO
DIFFERENT PLACES. THE FIRST POINT IS ON THE CROSS BASE
BEAM. THE SECOND POINT IS ON THE BASE OF THE UNIT BEHIND
THE CROSS BASE BEAM.
|
|
 |
STEP#3
USING FIBERGLASS LIFTING POLE PICK UP THE 3/8
ROPE IN THE CENTER. HANG THE ROPE ON THE HOOK. |
|
 |
STEP#4
PULL THE SLING UP TO THE HOOK. WITH THE ROPE GUIDE THE SLING
ONTO THE HOOK WITH THE POLL. |
|
 |
STEP#5
CONNECT RATCHET OR TURNBUCKLE TO THE SLING AND THEN TO THE
BASE-CLAMP
STEP#6
TIGHTEN SLING WITH RATCHET OR TURNBUCKLE; DO NOT LET SLING
TWIST-UP (NO
SLACK IN SLING). |
|
 |
STEP#7
RELEASE THE PUMPING UNIT BRAKE “VERY SLOWLY” TO INSURE
THAT ALL THE WEIGHT IS NOW LOADED ON THE CABLE. NOW RESET THE PUMPING
UNIT BRAKE.
THE PUMPING UNIT IS NOW SAFE
TO WORK ON OR AROUND. REVERSE THE PROCEDURE TO REMOVE THE TIE
DOWN SYSTEM FROM THE UNIT |
|
(MAKE EVERY DAY A SAFE DAY WORK DAY)
TOP |